When Does Night Rate Electricity Start, and How Long Should the Immersion Run?
By Technical Team, WEW, Ireland
On a standard NightSaver meter, night rate electricity typically runs 23:00 to 08:00 in winter and 00:00 to 09:00 in summer, a nine-hour window that shifts with the clocks; smart tariffs use similar night windows that vary by supplier. A 3 kW immersion heats a 120 litre cylinder in roughly two hours and a 300 litre cylinder in about five, so a single tank comfortably fits inside the night window at the cheaper rate.
When does night rate electricity start?
Night rate is a cheaper unit price for electricity used overnight, available on a night-rate meter or an equivalent smart tariff. The exact window depends on your meter and supplier, and the traditional NightSaver window moves by an hour with daylight saving. Treat the table as the common pattern and confirm your own plan.
| Meter / tariff | Typical night window | Notes |
|---|---|---|
| NightSaver (winter, GMT) | 23:00 to 08:00 | Nine hours, standard night meter |
| NightSaver (summer, DST) | 00:00 to 09:00 | Window shifts one hour with the clocks |
| Smart night tariff | Around 23:00 to 08:00 | Varies by supplier and plan |
| Smart EV / dedicated windows | Supplier-defined | May differ from the standard night band |
Typical Irish night-rate windows. Always confirm the exact hours and rates on your own plan. Last reviewed on the date shown above.
NightSaver or smart meter: which am I on?
Two kinds of meter give a night rate, and they behave differently. A traditional NightSaver meter has two registers, day and night, and switches automatically at the window above. A smart meter records usage every half hour and lets you take a time-of-use tariff, where the supplier defines the cheaper night band, and sometimes additional windows. If you are not sure which you have, your bill and plan name will say, and that determines the exact hours the cheaper rate applies.
How long should the immersion run?
Long enough to heat the cylinder once, no longer. A domestic immersion element is usually around 2.75 to 3 kW, and the heat-up time depends on the cylinder volume and how cold the water starts. The table shows approximate times to heat from cold (about 15°C) to a stored 60°C with a 3 kW element.
| Cylinder size | Energy to heat from cold | Approx time at 3 kW |
|---|---|---|
| 120 litres | ~6.3 kWh | ~2 hours |
| 210 litres | ~11 kWh | ~3 hours 40 min |
| 300 litres | ~15.7 kWh | ~5 hours 15 min |
Approximate, heating from ~15°C to 60°C at 3 kW, before standing losses. A timer avoids reheating water you will not use.
Use the timer, not the switch. Set the immersion to heat one tank inside the night window; leaving it on reheats cooling water at the day rate and wastes the saving.
Why heat the cylinder to 60°C?
There is a safety reason not to set the thermostat too low. Storing hot water below about 50 to 55°C lets Legionella bacteria multiply, so stored water is generally kept at around 60°C and delivered hot, as a control measure. Setting the immersion stat too low to save energy trades a small saving for a health risk, so the better levers are timing the heat to the night window and reducing standing losses, not lowering the temperature.
What does a tank cost to heat, and where do losses go?
The cost of heating a tank is the energy in kilowatt-hours multiplied by your unit rate, so the night rate is where the saving comes from. Using the figures above, heating a 210 litre cylinder takes about 11 kWh; at a night unit rate that is typically around half the day rate, that tank costs roughly half what it would on day-rate electricity. The other lever is standing loss, the heat a cylinder sheds while it waits to be used.
- Cost per tank = energy (kWh from the table) x your unit rate (check your bill).
- Night rate is usually around half the day rate, so timing the heat is the main saving.
- An immersion is pure resistive heating, so it is effectively 100% efficient; the losses are in storage, not the element.
- A good cylinder jacket or factory foam and lagged pipes keep the stored heat for the day, so a night-heated tank is still hot by evening.
What if the cylinder is also heated by a boiler, heat pump or solar?
Many cylinders have more than one heat source, and then the immersion is usually the backup or boost, not the main heater. If a heat pump or solar system is already warming the cylinder, running the immersion as well can waste money by reheating water that is already hot, so the immersion and its timer should be set to fill only the gap, overnight on the cheaper rate, rather than compete with the other source. Where the immersion is the sole heater, the night-window approach above gives the cheapest hot water.
How do I get the most from night rate?
- 1 Confirm your night window and your day and night unit rates from your plan.
- 2 Set a timer to heat the cylinder once inside the night window.
- 3 Keep the stat at around 60°C for Legionella control, and size the heated period to the cylinder.
- 4 Insulate the cylinder and pipework to cut standing losses so the stored heat lasts into the day.
Frequently asked questions
-
What time does night rate electricity start in Ireland?
On a standard NightSaver meter it typically runs 23:00 to 08:00 in winter and 00:00 to 09:00 in summer, a nine-hour window that shifts an hour with daylight saving. Smart night tariffs use similar windows that vary by supplier, so confirm your own plan. -
How long does it take an immersion to heat a tank?
With a 3 kW element heating from cold to 60°C, a 120 litre cylinder takes about two hours, a 210 litre about three and three-quarter hours, and a 300 litre about five and a quarter hours. A timer lets you fit the heat-up inside the cheaper night window. -
What temperature should an immersion thermostat be set to?
Around 60°C. Storing hot water below about 50 to 55°C allows Legionella bacteria to multiply, so the cylinder is generally kept near 60°C as a control measure. Rather than lowering the temperature to save energy, time the heating to the night rate and cut standing losses. -
How much does it cost to heat an immersion tank?
It is the energy used times your unit rate. Heating a 210 litre cylinder takes about 11 kWh, so on a night rate that is often around half the day rate, it costs roughly half what the same heat would cost on day-rate electricity. -
Should I run the immersion if I have a heat pump or solar?
Usually only as a backup or boost. If a heat pump or solar system already heats the cylinder, running the immersion as well reheats water that may already be hot. Set the immersion and timer to fill only the gap, overnight on the cheaper rate. -
Should I leave the immersion on all the time?
No. Leaving it on reheats cooling water repeatedly, often at the day rate, and wastes energy. Use a timer to heat one tank inside the night window and insulate the cylinder so the stored heat lasts through the day.